产品列表
浏览量:
产品名称
MYP矿用移动屏蔽橡套软电缆
编号
商品详细介绍
MYP矿用移动屏蔽橡套软电缆
Flexible shielding rubber-sheathed cables for mining purposes
型号(Type):MYP 额定电压(Rating Voltage):380/660V
Flexible shielding rubber-sheathed cables for mining purposes
型号(Type):MYP 额定电压(Rating Voltage):380/660V
芯数截面 Nom.cross sectional areas mm2 |
导体结构 Conductor structure NO./mm |
绝缘厚度 Insulation thickness mm |
护套厚度 Sheath thickness mm |
电缆外径 Average diameter |
参考重量 Cable approx. weight kg/km |
导体(铜)最大直流电阻 Max.D.C. resistance(20 ℃ ) Ω /km |
20 ℃载流量 Current carring capacity(20 ℃ ) A |
|
标称 Normianal mm |
最大 Max mm |
|||||||
3 × 4+1 × 4 |
56/0.30 |
1.4 |
3.5 |
22.9 |
25.2 |
730 |
4.950 |
35 |
56/0.30 |
4.950 |
|||||||
3 × 6+1 × 6 |
84/0.30 |
1.4 |
3.5 |
24.7 |
27.2 |
959 |
3.300 |
46 |
84/0.30 |
3.300 |
|||||||
3 × 10+1 × 10 |
84/0.40 |
1.6 |
4.0 |
29.7 |
32.7 |
1427 |
1.910 |
64 |
84/0.40 |
1.910 |
|||||||
3 × 16+1 × 10 |
126/0.40 |
1.6 |
4.0 |
32.2 |
35.4 |
1675 |
1.210 |
85 |
84/0.40 |
1.910 |
|||||||
3 × 25+1 × 16 |
196/0.40 |
1.8 |
4.5 |
38.3 |
41.0 |
2419 |
0.780 |
113 |
126/0.40 |
1.210 |
|||||||
3 × 35+1 × 16 |
276/0.40 |
1.8 |
4.5 |
42.4 |
46.6 |
2952 |
0.554 |
138 |
126/0.40 |
1.210 |
|||||||
3 × 50+1 × 16 |
396/0.40 |
2.0 |
5.0 |
47.4 |
51.0 |
3741 |
0.386 |
173 |
126/0.40 |
1.210 |
|||||||
3 × 70+1 × 25 |
360/0.50 |
2.0 |
5.0 |
52.4 |
57.1 |
4790 |
0.272 |
215 |
196/0.40 |
0.780 |
![]() |
备注:
1、电缆绝缘主线芯之间及主线芯与地线之间的绝缘电阻,换算到+20℃时不低于100MΩ·km。
2、主线芯屏蔽层的过渡电阻换算到20℃时不高于3kΩ。
3、产品标准:MT818.5-1999。
4、MYP型电缆有3个带绝缘屏蔽的主线芯和一个包覆半导电橡皮层的地线组成,围绕半导电橡皮层垫芯绞合成缆。外面挤包黑色氯化聚乙烯橡皮护套或黑色氯丁橡皮护套。
5、导电线芯:采用软铜线,其性能符合 GB/T3956-1997。
6、绝缘:采用GB7594.2-1987中XJ-00A型橡皮。
7、线芯识别:采用绝缘分色识别,主线芯红、绿、白。
8、地线:采用半导电橡皮包覆。
9、绝缘屏蔽:在绝缘表面包半导电带。
10、成缆:3个主线芯1个地线围绕半导电橡皮垫芯按右向绞合成缆。
11、护套:采用GB7594.7-1987中XH-03A型橡皮。护套橡皮的氧指数≥40。
12、成品电缆的阻燃性能满足MT386-1995的要求。
13、电缆标志:电缆表面印有型号、电压、规格及制造厂名称。
上一篇
MYJV22矿用交联聚乙烯绝缘钢带铠装聚氯乙烯护套电力电缆
MYJV矿用交联聚乙烯绝缘聚氯乙烯护套电力电缆
下一篇